04 Tower UPS AC208V AC220V AC240V

Zero-transfer time true double-conversion online UPS delivers comprehensive protection, safeguarding mission-critical equipment from diverse power quality issues. DSP-based digital control Advanced DSP-based digital control delivers high input power factor and low distortion performance, providing loads with a perfect sine wave AC power supply. Ultra-wide input voltage range Compatible with ultra-wide input voltages from 90V to 300V and 40Hz to 70Hz, significantly reducing battery discharge and maximizing battery life. Optimal load capacity Achieves an output power factor of up to 0.9. 40~70Hz compatibility significantly reduces battery discharge, extending battery life. Optimal loading capability with output power factor up to 0.9, 50/60 Hz.
Online Consultation

Details

Zero Transfer Time


True double conversion online UPS delivers comprehensive protection, safeguarding mission-critical equipment from all types of power quality issues


DSP-Based Digital Control


Advanced DSP-based digital control delivers high input power factor and low distortion performance, providing loads with a perfect sine wave AC power supply


Ultra-Wide Input Power Range


Compatible with ultra-wide input power ranges of 90V to 300V and 40 to 70Hz, significantly reducing battery discharge and extending battery life


Optimal Load Capacity


Output power factor up to 0.9, automatic 50/60 Hz adaptation, and selectable voltage options perfectly match diverse applications


Generator Compatibility


Works seamlessly with multiple generator sets, isolating fluctuations and noise to deliver stable, clean power to user equipment


High Input Power Factor


Digital control PFC technology achieves input power factor >0.99, effectively preventing power pollution and conserving energy



Parameters

Model

1K

1KS

2K

2KS

3K

3KS

Capacity

VA/W

1kVA/900W

2kVA/1.8kW

3kVA/2.7kW



Topology

Double Conversion Online UPS


Phase

Single Phase Input Single Phase Output

Mains Input

Wiring

L/N+PE


Rated Voltage

208/220/230/240VAC


Voltage Range

 90~300VAC


Frequency Range

40Hz~70Hz


Input Power Factor

≥0.99


AC Output

Wiring

L/N+PE


Output Voltage

208/220/230/240VAC


Voltage Regulation

±1%


Output Frequency

50/60±4Hz(Sync Mode) / 50/60Hz±0.1%(Free Run)


Waveform

Pure Sine Wave


Distortion

(THDV%)

<2%(Linear Load)


<7%(None-Linear Load)


Over load

 capability

1Min@105%~125%Rated Load

30Sec.@125%~150%Rated Load

0.5Sec.@>150%Rated Load


Efficiency

Line mode

88%

89%

90%


Battery Mode

86%

87%

88%


Battery

&

Charge

Rated Battery Voltage

24VDC

Internal

36VDC

External

48VDC

Internal

72VDC

External

72VDC

Internal

72VDC

External


Battery Capacity

7AHx2pcs

External Battery Depends 

7AHx4pcs

External Battery Depends 

7AHx6pcs

External Battery Depends


Backup Time

>6mins @ Half Load

>6mins @ Half Load

>6mins @ Half Load


Charging Current

Standard Model with Internal Battery:1A

Long Backup Time Model :4A


Optional Configuration to Order

1. External Battery Module Connector for Standards Model

2. Battery Capacity 7AH/9AH

3. Battery Quantity(2/4/6pcs) or (3/6/6pcs)


Physical

Chassis Style

Tower


Tower Dimension

1KS, 1K: 145(W)X220(H)x318(D)mm

 2KS, 2K, 3K, 3KS: 190(W) x 318(H) x 368(D)mm


Weight (kg)

8.4

4.7

16.2

10.5

21.2

12.0


HMI

LCD DISPLAY

Input Mains Voltage, Frequency, Load level, Operation Mode, Health Status


Standards

Communication Interface

1.RS232 PORT  2.EPO / ROO Port  3.Intelligent Slot  4.USB Card (not HID)


Optional Extension Card

5. NetWork Card:  Support SNMP/TCP/IP for remote monitoring the UPS via Smart Phone APP, Web page,  PC Monitor Software , Support Server / NAS shutdown

6. RS485-MODBUS Card,  LAN(TCP IP)-MODBUS Card,

7. Mini AS400 Relay Card  


Operating Environment

Endurance

Temperature range

-10~50oC


Relative Humidity

0-98%Non-condensing


Acoustics Noise

<55dB @ 1 meters


 